Username Password SUBMIT Remember Me Sign up
Login
Enter Zip/Postal Code GO Outside the U.S. and Canada?
Logging in ...
Benefits
TrilliumSeries™ Adiabatic Condenser Bookmark and Share

Lowest Energy and Water Usage

  • Lowest Monthly Energy Usage
    • Lowest condensing temperatures year round, save the most compressor energy
    • Direct drive VSEC motors minimize fan energy requirement
    • Helps increase compressor life by lowering refrigeration temperatures (compared to AC)

      Annual 37.2% System Energy Reduction for El Paso, Texas

      Annual 37.2% System Energy Reduction for El Paso, Texas

  • Lowest Peak Energy Usage

    • Up to 44% peak energy reduction compared to air cooled units by operating compressors at significantly lower condensing temperatures
    • Peak energy is more expensive than off peak energy
    • Potential for substantial state and local energy rebates

      Average Payback Period by Region

      Average Payback Period by Region

  • Subcritical Operation with CO2
    • Minimize transcritical operation using the CO2 TrilliumSeries™ Adiabatic Condenser. In many cases, transcritical operation can be reduced to less than 5 hours per year.

      Hours Spent in Subcritical

      Hours Spent in Subcritical

  • Average Annual Water Use – TrilliumSeries vs. Evaporative Condensers
    •  Uses water on only the hottest days reduces consumption by more than half
    • Cleansing circulation minimizes water usage while keeping the Pre-Cooler Pads and unit clean

      Water Usage

      Water Usage

Owner Benefits

  • Lowest Total Cost of Ownership

    • Payback

      Lowest Total Cost of Ownership – Quickest Payback


    • Rebates
      • Most states offer utility incentives and rebates which further decrease initial investment.
      • Visit www.dsireusa.com to see what rebates are available.
  • Lowest Installation Cost

    Example 700 MBH Evaporator Load, Sacramento, CA, R404a

    Example 700 MBH Evaporator Load, Sacramento, CA, R404a

  • Lowest Refrigerant Charge
    • 90% less charge than comparable air cooled or evaporative condensers with the microchannel coils
    • Reduced charge could help meet EPA’s Greenchill commitments
    • Lowers greenhouse gas emissions of the supermarket refrigeration system
    • Fluid cooler models available to support propane, or other contained-charge systems
    • Avoid PSM issues on ammonia installations

      Lowest Refirgerant Charge

      Lowest Refrigerant Charge

  • Easy Maintenance

Featured Content